background image

PRT32 v1.0 fv74.7 Rev. A EN 

 

7/3/2009 

_________________________________________________________________________________________  

 
 

 

Page 16 of 29   

 

Each key pressed is 

transmitted separately, 

no control bits added 

Each key pressed is immediately transmitted to the host controller as 
a sequence of 4 bits (XXXX) which represent the code of the pressed 
key, no control bits added. This format is compatible with HID 5355 
series readers, option: Without Parity

Note: The PIN code transmission options described in this table apply to 26/34/42/66bit Wiegand data formats 
only. 

 

When the reader is set for Stand-alone mode (Offline), installer must program to a 

reader two special cards; MASTER and INSTALLER and then enter the Installer 

Programming mode in order to make final configuration settings. The programming 

of the cards and PINs can be carried out in the User Programming mode. 

Note: If you observe that after selection of a reader’s operation mode or after 

power up of a unit, the LED SYSTEM   is on and accompanied with acoustic signal 

it means that the contents of reader’s memory is corrupted or the 

MASTER/INSTALLER card are not programmed. In this case you must perform the 

full Memory Reset and completely re-program a reader. 

7.4.

 

Memory Reset - programming MASTER and INSTALLER 
users 

The Memory Reset erases all cards and PINs including MASTER and INSTALLER 

users. Also, it causes the reader restores the factory-shipped default settings. The 

Memory Reset has practical sense for Offline modes only, it does not affect the unit 

if it is configured for Online mode. 

To perform Memory Reset follow these steps: 

 

Power down the unit 

 

Check the jumpers and assure that reader is configured to either Full stand-

alone or Simple stand-alone mode, if not select appropriate standalone mode  

 

Once configured to standalone mode place jumper on JP1 contacts 

 

Restart the reader (switch power off and on), reader will generate a continuous 

beep 

 

Wait until the LED OPEN   starts flashing 

 

Remove jumper from JP1 contacts 

 

Enter new MASTER PIN (3-6 digits) or skip this step and go to next one  

 

Present any card to the reader — this card becomes a new MASTER card or 

press [#] and go to the next step 

 

Enter new INSTALLER PIN (3-6 digits) or skip this step and go to next one  

 

Present another (second) card to the reader — this card becomes a new 

INSTALLER card or press [#] and go to the next step 

 

Once the previous step has been completed reader automatically ends the 

Memory Reset and enters the Armed mode 

7 . 4 . 1 .

 

F a c t o r y   d e f a u l t   s e t t i n g s  

Once the Memory Reset is competed the reader restores the following factory-

shipped default settings: 

 

Door unlock time

: 4 sec. 

Содержание PRT32

Страница 1: ...PRT32 v1 0 RFID PIN Access Reader Firmware v74 7 Installation and Programming Guide...

Страница 2: ...rs 8 6 2 Managing the users 9 6 3 User identification 9 6 4 Armed and Disarmed Modes 10 6 5 Arming and disarming of a reader 10 6 5 1 Examples 11 6 6 Unlocking a door 11 6 7 Operation with XM 2 I O ex...

Страница 3: ...power up of the reader the LED SYSTEM is on it means that either contents of reader s memory is corrupted or MASTER INSTALLER users are not programmed into a unit In this case reader must be complete...

Страница 4: ...ble to operate with XM 2 I O module nor additional PRT reader 4 General 4 1 Designed function The PRT32 reader has been designed for use in access control installations to enable user identification v...

Страница 5: ...ns for transmission of PIN codes LED BUZZER control input Offline mode Stand alone mode System settings stored in nonvolatile memory Enrolment up to 120 users User identification by a card or PIN code...

Страница 6: ...e code PIN As a result transmission from a reader is not equal to a full code of presented card code or entered PIN In Wiegand format a dual color LED STATUS lights steady in red The LED SYSTEM along...

Страница 7: ...essed Each entry of PIN code must be followed by pressing the key which is treated as the end of a PIN code In RACS format when IN1 is triggered the PRT32 will stop reading cards and PINs till the mom...

Страница 8: ...CLK DTA and IN1 can be configured fro several available functions Note The CLK and DTA lines may operate either as an input or output Installer has to program each line for adequate function The funct...

Страница 9: ...OGGLE LIMITED are solely authorized to control the Armed Disarmed mode of the reader they may have card and or PIN 6 2 Managing the users A new user can be registered in the device following either a...

Страница 10: ...general the reader s Armed Disarmed states have no effect on door unlocking unless the Access disabled when reader armed option will be enabled With this option activated access to the supervised roo...

Страница 11: ...the LED STATUS will change color Note If the option Access disabled when reader armed is enabled and the reader is in Armed mode then in order to unlock a door first you will have to switch the reader...

Страница 12: ...isarmed to Armed mode in order to disable unlocking of a door 6 7 Operation with XM 2 I O extension module In Full stand alone mode the PRT32 requires connection to an external XM 2 I O extension modu...

Страница 13: ...f the reader operates with a Door Contact The alarm indication is carried out over the Alarm Output line and optionally accompanied by the internal buzzer see option Door alarm indication on internal...

Страница 14: ...Offline mode If the unit is dedicated for Offline mode the installer must perform four programming steps Setting the reader to required Offline mode either Full or Simple stand alone mode Programming...

Страница 15: ...RACS data formats the JP1 and JP2 jumpers are used to specify reader s address ID number Note 2 For both Simple and Full stand alone modes the JP1 jumper is used to enter the Memory Reset procedure JP...

Страница 16: ...der 7 4 Memory Reset programming MASTER and INSTALLER users The Memory Reset erases all cards and PINs including MASTER and INSTALLER users Also it causes the reader restores the factory shipped defau...

Страница 17: ...tion mode selected for the reader either Simple Stand alone Mode or Full Stand alone mode the configuration digits C5 and C6 may have different effects for Simple Stand alone mode they configure the r...

Страница 18: ...exist output indicates alarm with a highest priority 7 Door Bell output whenever the door bell event occurs this output goes on for approx 5 seconds C6 0 7 Function settings for the REL2 output on the...

Страница 19: ...d Option Access disabled when reader armed disabled Last step completes the programming and the reader automatically leaves Installer Programming mode and returns to the operating mode either Armed or...

Страница 20: ...first unoccupied memory location with entered PIN his ID number is unknown 4 PIN Add single TOGGLE LTD user with a PIN only The new TOGGLE LTD user is stored in a first unoccupied memory location wit...

Страница 21: ...user with entered ID The user with entered ID is deleted both his card and his PIN are removed a new user can be programmed to use this ID index 0 Delete all users Reader deletes all users cards and P...

Страница 22: ...ong signal Error unknown identifier access denied Two long signals Attempt to assign the same function for two different input lines Three short beeps Command successfully completed OK signal Two shor...

Страница 23: ...ALLER users can be skipped A new factory delivered unit is configured for RACS Online mode with address ID 0 Disconnect power supply before making any electrical connections For installations on a met...

Страница 24: ...IN1 line activated by shorting it with the supply minus When IN1 is triggered it turns the LED OPEN to on and also activate acoustic signal on the internal buzzer TAMP Isolated tamper switch contacts...

Страница 25: ...ule is delivered with plastic box XM 2 Brd The XM 2 PCB module without casing Product History Hardware Firmware Date Description PRT32 v1 0 71 00 18 04 05 The initial product version PRT32 v1 0 72 00...

Страница 26: ...A EN 7 3 2009 _________________________________________________________________________________________ Page 26 of 29 Table List of users Site name Reader location ID Number Card number PIN Type User...

Страница 27: ...PRT32 v1 0 fv74 7 Rev A EN 7 3 2009 _________________________________________________________________________________________ Page 27 of 29...

Страница 28: ...PRT32 v1 0 fv74 7 Rev A EN 7 3 2009 _________________________________________________________________________________________ Page 28 of 29...

Страница 29: ...PRT32 v1 0 fv74 7 Rev A EN 7 3 2009 _________________________________________________________________________________________ Page 29 of 29...

Отзывы: