PRT32 v1.0 fv74.7 Rev. A EN
7/3/2009
_________________________________________________________________________________________
Page 16 of 29
Each key pressed is
transmitted separately,
no control bits added
Each key pressed is immediately transmitted to the host controller as
a sequence of 4 bits (XXXX) which represent the code of the pressed
key, no control bits added. This format is compatible with HID 5355
series readers, option: Without Parity.
Note: The PIN code transmission options described in this table apply to 26/34/42/66bit Wiegand data formats
only.
When the reader is set for Stand-alone mode (Offline), installer must program to a
reader two special cards; MASTER and INSTALLER and then enter the Installer
Programming mode in order to make final configuration settings. The programming
of the cards and PINs can be carried out in the User Programming mode.
Note: If you observe that after selection of a reader’s operation mode or after
power up of a unit, the LED SYSTEM is on and accompanied with acoustic signal
it means that the contents of reader’s memory is corrupted or the
MASTER/INSTALLER card are not programmed. In this case you must perform the
full Memory Reset and completely re-program a reader.
7.4.
Memory Reset - programming MASTER and INSTALLER
users
The Memory Reset erases all cards and PINs including MASTER and INSTALLER
users. Also, it causes the reader restores the factory-shipped default settings. The
Memory Reset has practical sense for Offline modes only, it does not affect the unit
if it is configured for Online mode.
To perform Memory Reset follow these steps:
•
Power down the unit
•
Check the jumpers and assure that reader is configured to either Full stand-
alone or Simple stand-alone mode, if not select appropriate standalone mode
•
Once configured to standalone mode place jumper on JP1 contacts
•
Restart the reader (switch power off and on), reader will generate a continuous
beep
•
Wait until the LED OPEN starts flashing
•
Remove jumper from JP1 contacts
•
Enter new MASTER PIN (3-6 digits) or skip this step and go to next one
•
Present any card to the reader — this card becomes a new MASTER card or
press [#] and go to the next step
•
Enter new INSTALLER PIN (3-6 digits) or skip this step and go to next one
•
Present another (second) card to the reader — this card becomes a new
INSTALLER card or press [#] and go to the next step
•
Once the previous step has been completed reader automatically ends the
Memory Reset and enters the Armed mode
7 . 4 . 1 .
F a c t o r y d e f a u l t s e t t i n g s
Once the Memory Reset is competed the reader restores the following factory-
shipped default settings:
•
Door unlock time
: 4 sec.