2.
Important note – read this first
The PRT32 can be configured for various operating modes. The factory shipped new
reader is pre-configured for
RACS address ID=0
. The selection of the required
operating mode can be carried out through adequate programming procedure (see
Setting reader operating mode
later in this document).
If the reader is dedicated for Offline mode (standalone mode) installer must
program two special users (MASTER and INSTALLER) into a unit, those users will be
later required for programming of a unit.
If the unit is dedicated for Online mode (slave unit connected to the host controller)
programming of the MASTER and INSTALLER users is not necessary.
Both users (MASTER and INSTALLER) may have card and/or PIN. Any EM 125 kHz
proximity card or tag can be programmed for MASTER or INSTALLER. Whenever
required (e.g. when stolen or lost) installer may program new MASTER and
INSTALLER cards into a unit. The factory new PRT32 reader is shipped with MASTER
and INSTALLER users not programmed.
Note: If after power up of the reader the LED SYSTEM is on it means that either
contents of reader’s memory is corrupted or MASTER/INSTALLER users are not
programmed into a unit. In this case reader must be completely re-programmed.
3.
Glossary and terms
Clock & Data Interface
The electrical interface used by the reader for communication with various
equipment connected to it. Optionally, the PRT32 can operate with a second PRT
series reader and XM-2 I/O extension module. These devices can be connected to
the same Clock and Data lines and must have an individual addresses (ID
numbers).
Door Release or Door Lock
The electric device used to unlock a door. Typically it can be a door strike or
magnetic lock.
Identifier
The method or means which is used for identification of a user. It can be a
proximity card, a PIN code, a finger template etc. In some cases Identifier may
consist of two or more of items required for a single identification procedure. For
example when the option Card and PIN is active then Identifier=Card+PIN.
Identification Mode
The method used for identification of users. The PRT32 offers following
Identification Modes: Card or PIN and Card and PIN.
Memory Reset
The procedure which clears contents of device’s memory and restores default
(factory) values.
PRT Series Readers
The PRT reader’s family developed and manufactured by the Roger. Each member