PRT32 v1.0 fv74.7 Rev. A EN
7/3/2009
_________________________________________________________________________________________
Page 14 of 29
Alarm duration is last app. 3 minutes, regardless of the alarm type. Each alarm can
be stopped by using any from of identifier registered in the reader. The Door Ajar
alarm is also immediately stopped, once the door is closed. If more than one alarm
is triggered, the reader indicates the alarm with the highest priority.
7.
Programming
The programming steps which are required for PRT32 reader depends on the
operating mode to which it was configured for. The PRT32 can not be programmed
from PC, it can be only programmed manually from its keypad.
Note: The programming of a reader can be done on primary reader only.
7.1.
Preparing the reader for Online mode
If the unit is dedicated for Online mode the only one programming step which is
required is setting the reader’s operating mode.
7.2.
Preparing the reader for Offline mode
If the unit is dedicated for Offline mode the installer must perform four
programming steps:
•
Setting the reader to required Offline mode (either Full or Simple stand-alone
mode)
•
Programming the MASTER and INSTALLER users
•
Configuring the reader for specific installation scenario (Installer Programming)
•
Programming cards and/or PINs (User Programming)
7.3.
Setting the reader’s operating mode
The settings of the reader operating mode is achieved on programming jumpers.
The factory new reader is pre-configured for
RACS Online
operation mode with
address
ID=0
.
Jumper
settings
Operating mode
Description
Offline mode,
Simple Stand-alone mode
The reader operates in the Stand-alone mode, the CLK
and DTA lines serve as ordinary I/O lines.
Offline mode,
Full Stand-alone mode
The reader operates in the Stand-alone mode, the CLK
and DTA lines are used for communication with remote
XM-2 I/O and optional (secondary) PRT reader.
Online mode,
RACS communication interface,
address ID=0
The reader operates as a slave reader connected to a
host controller that requires RACS data transmission
format.
Online mode RACS
communication interface,
address ID=1