PRT32 v1.0 fv74.7 Rev. A EN
7/3/2009
_________________________________________________________________________________________
Page 19 of 29
Note: Depending of the selected reader operating mode (either Full stand-alone or
Simple stand-alone) the parameters C5 and C6 may refer to REL1 and REL2 output
lines on remote XM-2 I/O extension module or to CLK and DTA lines located on a
reader.
Example: Configuring the reader in the Installer Programming mode
Read your INSTALLER card once, the reader enters Installer Programming mode
(the LED OPEN is on and the LED STATUS
lights in green) then enter following
sequence of 13 digits: 0206451230001. Those digits configure the reader for
following options:
•
Door unlock time
: 02 sec.
•
Door open timeout
: 06 sec.
•
CLK or REL1 line function:
Door lock
output
•
DTA or REL2 line function:
Disarmed Mode
output
•
Line IN1 on the reader:
Door Contact
input
•
Line IN1 on the XM-2 module:
Exit Button
input
•
Line IN2 on the XM-2 module:
Arming Disabled
input
•
Identification Mode on primary reader:
Card or PIN
•
Identification Mode on secondary reader:
Card or PIN
•
Option
Door alarm indication on internal buzzer
disabled
•
Option:
Access disabled when reader armed
disabled
Last step completes the programming and the reader automatically leaves Installer
Programming mode and returns to the operating mode (either Armed or Disarmed)
in which it was in before entering Installer Programming.
Note: Installer Programming can be accessed only if the reader was earlier
configured for either Full Stand-alone or Simple Stand-alone mode.
7.6.
User Programming mode
The User Programming mode is dedicated to manage users registered in the reader
(add and delete cards and PINs). To enter this mode read the MASTER card or
enter MASTER PIN code. Once in User Programming mode, the LED OPEN is on
and the LED STATUS
lights in red.
In the User Programming mode you have 12 programming commands to choose
from. Once you enter any programming function the LED SYSTEM starts flashing
and it keeps flashing till command sequence has been successfully completed. If
the reader receives no valid entries for more than 20 sec. (between the successive
steps of the command sequence), it will automatically end the command sequence.
However, it will still remain in User Programming mode so that you may return to
any user programming command or you may press [#] to exit this programming
mode, alternatively you may wait ~150 sec. for the reader to leave User
Programming mode automatically.