i. The vacuum level drops under 10% ;
ii. The object status is 0. This means that the vacuum level dropped under the minimum level for more than 0.1 second.
When releasing an object in the manual mode, the Vacuum Gripper will:
1
Open the release valve.
2
Object drop flag will be set when the vacuum level falls below 0.5%.
3
Release valve will be kept open for 0.1 second.
45