Proprieties
Value
Baud rate
1.2KBps to 10500KBps; Default:115.2 KBps
Data bits
8 bits
Parity
None, Odd, Even; Default: None
Stop bit
1 or 2 bit; Default: 1 bit
Other Modbus functions
FC4, FC6, FC16, FC23,
Exception responses
0x03 (Illegal Data Value)
Slave ID
1 to 9: Default: 9
Robot output/Gripper input
registers
1000 to 1007
Robot input/Gripper output
registers
2000 to 2007
Table 4-2: Modbus RTU connection setup for the Vacuum Gripper
4.7.2. Read input registers (FC04)
The function code 04 (FC04) is used to request the status of the Vacuum Gripper's analog input register. Examples of use of these
data are the Vacuum Gripper status, the object status, etc.
Example of FC04 read function:
This message asks for register 0x07D0 (2000) and register 0x07D1 (2001) which contain Gripper Status, Object Detection, Fault
Status and Maximum Relative Pressure Level Request Echo.
Request is: 09 04 07 D0 00 02 70 0E
Bits
Description
09
Slave ID
04
Function Code 04 (Read Input Registers)
07D0
Address of the first requested register
0002
Number of registers requested (2)
49
Содержание AirPick
Страница 25: ...Fig 3 7 Mounting air nodes suction cups air bolts air nuts on the bracket 25...
Страница 27: ...Fig 3 9 Robotiq Vacuum Gripper with pigtail cable and device cable wiring scheme 27...
Страница 35: ...Fig 4 1 Vacuum Gripper control logic overview 35...
Страница 57: ...7 Click on the New Project icon in the upper left corner of the screen 57...
Страница 58: ...AirPick Instruction Manual 8 Enter a name for your program and click on the OK button 9 58...
Страница 76: ...Fig 6 5 Minimum and maximum arrangement possibilities of the air nodes position 76...
Страница 77: ...AirPick Instruction Manual 6 1 3 Air nodes Fig 6 6 Air nodes dimensions 77...
Страница 103: ...AirPick Instruction Manual 12 Appendix Fig 12 1 Pneumatic schema of the AirPick Vacuum Gripper...