Summary
Condensing boilers . . . . . . . . . . . . 2
Modular condensing boiler . . . . . . . . . 3
Packaging content. . . . . . . . . . . . . 3
aiM 65 . . . . . . . . . . . . . . . . . 4
aiM 85, aiM 115, aiM 150 . . . . . . . . . . 5
Operational functios . . . . . . . . . . . . 6
Operation and main safety systems . . . . . . 7
Antifreeze function . . . . . . . . . . . . 7
Boiler Panel and Human Machine Interface . . . 8
Description of the function keys . . . . . . . 9
Technical specifications. . . . . . . . . . 11
Energy technical specifications . . . . . . . 12
Dimensions . . . . . . . . . . . . . . 13
Characteristic curve of the circulator . . . . . 15
Boiler pressure drops . . . . . . . . . . 16
Unpacking the generator . . . . . . . . . 17
Wall mounting and fixing . . . . . . . . . 17
Distances of respect . . . . . . . . . . . 17
Installation . . . . . . . . . . . . . . . 18
General safety warnings . . . . . . . . . 18
General safety warnings . . . . . . . . . 19
Messa in opera . . . . . . . . . . . . . 21
Feed water characteristics . . . . . . . . 22
Connection to the heating system. . . . . . 22
Condensate drain connection and safety valve 24
Gas supply circuit . . . . . . . . . . . . 25
Electrical connection . . . . . . . . . . . 27
Wiring diagram . . . . . . . . . . . . . 28
Electronic connections on the back of the control
panel . . . . . . . . . . . . . . . . . 29
Flue systemt . . . . . . . . . . . . . . 30
Sizing of the single heat generator flue system 31
Sizing of the battery flue system . . . . . . 32
Regulation and control system . . . . . . . 33
Accessing The Menus . . . . . . . . . . 34
End user menu parameters . . . . . . . . 34
Parameters Menu Commissioning . . . . . 35
Specialist Menu Parameters . . . . . . . . 36
Cascade connection . . . . . . . . . . . 37
Extension module . . . . . . . . . . . . 38
Fuel gas pressure control . . . . . . . . . 40
Rinnai Italia srl declines all responsibility for possible inaccuracies deriving from printing or transcription errors and reserves the right to make changes to its
products, without notice, that it deems necessary or useful without compromising their essential characteristics.
This edition cancels and replaces any previous edition.
Check generator calibration . . . . . . . . 40
Gas valve adjustment . . . . . . . . . . 41
Gas conversion . . . . . . . . . . . . . 41
Maintenance . . . . . . . . . . . . . . 42
Front panel disassembly . . . . . . . . . 42
Disassembly of the side panels. . . . . . . 42
Disassembly of the heat exchanger . . . . . 43
Fault codes . . . . . . . . . . . . . . 44
Indicative diagrams of operation . . . . . . 45
AiM 65 wall-mounted condensing boiler . . . 57
AiM 85 wall-mounted condensing boiler . . . 58
Содержание aiM 115
Страница 1: ...Modular boilers User and installation manual Indoor models aiM 65 aiM 115 aiM 85 aiM 150 ...
Страница 17: ...13 Technical data Dimensions FRONT VIEW REAR VIEW TOP VIEW BOTTOM VIEW HEIGHT DEPTH ...
Страница 65: ......
Страница 66: ...Via Liguria 37 41012 Carpi Modena Tel 059 622 9248 e mail info rinnai it rinnai it 200626 ...