44
Service
Fault codes
In the event of a fault, this symbol .
By pressing the INFO button, the specific error code and a brief description appear on the display on the machine.
In the event of an error code, please contact an Rinnai Authorized service.
The last 20 error codes can be viewed by accessing the Faults category from the Specialist Menu starting from parameter
6800
.
The following table shows the error codes that may arise:
Error code
Description
10
External probe
20
Boiler temperature 1, sensor error
26
Common flow temperature, sensor error
28
Flue gas temperature, sensor error
30
Flow temperature1, sensor error
32
Flow probe 2, sensor error
40
Return temperature2, sensor error
46
Cascade return temperature, sensor error
47
Common return temperature, sensor error
50
DHW temperature1, sensor error
78
Water pressure, sensor error
84
LPB wire address collision
98
Extension module 1
99
Extension module 2
100
Main time (LPB)
105
Maintenance message
109
Supervision boiler temperature
117
Water pressure too high
118
Water pressure too low (critical limit)
121
Flow temperature heating circuit 1
127
Legionella temperature not reached
128
Loss of flame during operation
129
Wrong air supply
130
Flue gas temperature limit exceeded
178
Temperature limiter heating circuit 1
209
Fault heating circuit
217
Sensor error
218
Pressure supervision
243
Swimming pool sensor, error
324
Input BX, same sensor
Error code
Description
327
Extension module, same function
330
Sensor input BX1 without function
331
Sensor input BX2 without function
332
Sensor input BX3 without function
333
Sensor input BX4 without function
335
Sensor input BX21 without function
336
Sensor input BX22 without function
339
Collector pump Q5 missing
340
Collector pump Q16 missing
341
Sensor B6 missing
343
Solar integration missing
351
Primary controller / system pump, address error
353
Sensor B10 missing
371
Flow temperature heating circuit 3
373
Extension module 3
386
Fan speed tolerance
387
Air pressure tolerance
388
DHW sensor no function
429
Dynamic water pressure too high
430
Dynamic water pressure too low
431
Sensor primary heat exchanger
432
Function earth not connected
433
Temperature primary heat exchanger too high
Содержание aiM 115
Страница 1: ...Modular boilers User and installation manual Indoor models aiM 65 aiM 115 aiM 85 aiM 150 ...
Страница 17: ...13 Technical data Dimensions FRONT VIEW REAR VIEW TOP VIEW BOTTOM VIEW HEIGHT DEPTH ...
Страница 65: ......
Страница 66: ...Via Liguria 37 41012 Carpi Modena Tel 059 622 9248 e mail info rinnai it rinnai it 200626 ...