10
Range overview
Description of the function keys
Info button
The INFO key allows you to view on the
display, placed on the machine, some
information that depends on the system
configuration and from components that
is connected to the heat generator.
By pressing the INFO button, they can
be shown:
•
error messages;
•
maintenance messages;
•
operational messages;
•
room temperature;
•
boiler temperature;
•
external temperature;
•
DHW temperature;
•
heating status;
•
DHW status;
•
boiler status;
•
solar state;
•
date and day;
•
telephone assistance center, if
pre-set.
Reset Button
By pressing the Reset key, the message
“Reset Event” will appear on the display.
This restores the Factory Default
Settings.
Also boiler and fan will perform control
cycles.
Manual control button
When the CONTROL key is activated
MANUAL, the heat generator comes
set with the maximum temperature flow
selected by the end user on the control
panel.
After activating the function manual
control, will appear on the display the
symbol
.
By pressing the INFO button it will be
possible to change the temperature of
set point.
Chimney sweep function key
By pressing the function key CHIMNEY
SWEEP for 3 seconds, the heat
generator goes to maximum power to
check correct fuel gas supply e adjust
the air - fuel ratio.
After activating this function, on the the
display will show “Function Chimney
sweep ON ”with the symbol.
.
To deactivate the function chimney
sweep press the again key and be sure
to read the writing “Chimney sweep
function OFF”
Main symbols that appear on the
display
The symbols present on the control
panel will come briefly explainedIn this
paragraph.
Xxxxxxxxxxxxxxxxxxxxxxxxxxx
Xxxxxxxxxxxxxxxxxxxxxxxxxxx
Xxxxxxxxxxxxxxxxxxxxxxxxxxx
1
2
PROG
ECO
INFO
No
Symbol
Description
Sun
Active heating in
Comfort mode
Moon
Active heating in
reduced mode
Home
Active heating
in anti-freeze
protection
Hourglass
Wait
Stack
Low battery
Flame
Active burner
INFO
Active level
information
PROG
Active programming
ECO
Heating functions
temporarily
disabled. ECO
function active
Suitcase
Active holiday mode
Radiator
Reference to the
heating circuit
Wrench
Service mode active
Bell
Error message
Display of error codes
Error 30:
Flow sensor 1
In case the heat generator goes to
block, the display will show symbol .
When this symbol appears, pressing
the INFO button is possible view the
error code you are getting manifesting.
Please see the error code table for
explanation of the anomaly.
Содержание aiM 115
Страница 1: ...Modular boilers User and installation manual Indoor models aiM 65 aiM 115 aiM 85 aiM 150 ...
Страница 17: ...13 Technical data Dimensions FRONT VIEW REAR VIEW TOP VIEW BOTTOM VIEW HEIGHT DEPTH ...
Страница 65: ......
Страница 66: ...Via Liguria 37 41012 Carpi Modena Tel 059 622 9248 e mail info rinnai it rinnai it 200626 ...