51
Design indication
Indicative diagrams of operation
Heat production circuit
A
DHW production circuit
B
HC circuit - Direct
C
HC circuit - Mixed n ° 1 (MIX)
D
A
B
A2
B6
A3
INAIL
C
C6
D
D5
D2
D6
D4
B3
B6
B7
Alimentazione
Acqua Fredda
MIX
B4
B8
PE
P
E
External boiler pump
Pos. Description
Circ.
A
Boiler (aIM)
0
A
2
External temperature sensor
Accumulation temperature sensor
B
3
DHW circuit pump
B
6
A
3
Flow temperature sensor
B
External extension module 2
4
DHW circuit recirculation pump
B
7
DHW circuit recirculation probe
B
8
Direct circuit pump
C
6
D
2
5
6
D
D
Contact temperature sensor
Mixing valve
Contact temperature sensor
D
External extension module 1
4
Pos. Description
Circ.
06- JAN. SINGLE - MANAGEMENT OF DIRECT CIRCUIT, MIXED CIRCUIT AND BOILER LOAD WITH RECRUITMENT
Hydraulic scheme
Wiring diagram
SIG
N
A
L
LIN
E T
ER
M
IN
A
L
1
2
3
4
5
6
7
8
9
1
0
11
1
2
1
2
3
4
5
6
7
8
9
10
1
1
1
2
13
14
15
1
6
1
7
1
8
19
2
0
21
22
23
24
2
5
2
6
2
7
28
13
1
4
15
16
17
1
8
1
9
20
2
1
2
2
23
24
25
2
6
2
7
28
POWER SUPPLY
230V
HEATING CIRCUIT
PUMP(QX2)
DHW PUMP (QX3)
BOILER PUMP
HIGH EFFICIENCY (QX1)
MODULATING BOILER PUMP
CASCADE SENSOR (BX1)
DHW SENSOR (B3 / B38)
OUTSIDE TEMPERATURE
SENSOR (B9)
DIGITAL INPUT
(Room thermostat)
ROOM UNIT
ANALOG SENSOR
MODULATING PUMP SENSOR
PE
C6
A2
B6
A3
B3
ζ
ζ
ζ
Electronic programming
Description
Parameter
Selection
Standard Value
Value to set
Heating circuit 2
1010
Comfort setpoint
20°C
Between 18 and 22 ° C
1012
Reduced setpoint
16°C
Between 15 and 18 ° C
1020
Heating curve slope
1,5
1.5 Radiators / 0.8 Floor
1041
Flow temp setpoint max
40°C
Radiators 70 ° C / Floor 50 ° C
Domestic Hot Water
(DHW)
1610
Nominal setpoint
55°C
Between 55 and 65 ° C
1640
Legionella function
Recurring
Based on needs
1641
Legionella funct periodically
3 days
Based on needs
1642
Legionella funct weekday
Sunday
Based on needs
1644
Legionella funct time
03:00
Based on needs
1645
Legionella funct setpoint
65
Based on needs
1646
Legionella funct duration
30 min
Based on needs
1660
Circulating pump release
On
Time slots set
1663
Circulating setpoint
45°C
Based on needs
Configurazione
5890
Relay output QX1
-
External boiler pump Q1
5891
Relay output QX2
-
Heating circ. Pump 1 Q2
5892
Relay output QX3
-
Accumulation loading pump Q3
5930
Sensor input BX1
Collector sensor B6
5931
Sensor input BX2
Storage tank temperature sensor B31
Содержание aiM 115
Страница 1: ...Modular boilers User and installation manual Indoor models aiM 65 aiM 115 aiM 85 aiM 150 ...
Страница 17: ...13 Technical data Dimensions FRONT VIEW REAR VIEW TOP VIEW BOTTOM VIEW HEIGHT DEPTH ...
Страница 65: ......
Страница 66: ...Via Liguria 37 41012 Carpi Modena Tel 059 622 9248 e mail info rinnai it rinnai it 200626 ...