Requirements and conditions
Electrical connection
For all heat generators the power supply must be 220V (+
10%) and 50Hz, single phase and must be present the earth
connection.
The boiler meets the following requirements:
•
Low voltage directive 2014/35 / UE
•
EMC directive on electromagnetic compatibility 2014/30 /
EU
Wiring must be done by a qualified technician. is necessary:
•
respect the connection L (Line) - N (Neutral) e connections
of the earth (Ground).
•
use cables with a section greater than or equal to 1.5mm2,
complete with ferrule terminals;
•
refer to the diagrams shown in this manual for any
interventions on the electrical system;
•
connect the appliance to an effective earth system.
The boiler is equipped with special connectors, located in the
lower part of the appliance, which facilitate installation. Some
specific elements must be connected to them on the system.
Each connector has a special label in which the component
to be connected is indicated to the heat generator that will
manage every function in in relation to the specific parameters
already pre-set, or to be set according to the needs of the
customer.
All the components connected to the electronics of the
appliance must not have an absorption greater than 2A of
current.
The table below shows the characteristics of the wiring from
use for probes.
Intersection area
Maximum lengths
0.25 mm
2
20 m
0.5 mm
2
40 m
1 mm
2
80 m
1.5 mm
2
120 m
SIG
N
A
L
LIN
E T
ER
M
IN
A
L
1
2
3
4
5
6
7
8
9
10
11
1
2
1
2
3
4
5
6
7
8
9
10
11
1
2
13
14
15
1
6
17
18
1
9
20
21
22
23
24
25
26
27
2
8
13
14
15
1
6
17
18
1
9
20
21
22
23
24
25
26
27
2
8
POWER SUPPLY 230V
HEATING CIRCUIT PUMP
DHW PUMP
HIGH EFFICIENCY BOILER PUMP
MODULATING BOILER PUMP
POWER SUPPLY 230V
QX2
QX3
QX1
AUX2
BX1
B3/B38
B9
H5
BSB BUS
BX2
NOT ASSIGNED
P1 PWM
COLLECTOR SENSOR
B3 / B38 DHW SENSOR
EXTERNAL PROBE
DIGITAL INPUT (Room thermostat)
ROOM UNIT
ANALOG SENSOR
NOT ASSIGNED
MODULATING BOILER PUMP
Electronic connections on the back of the control panel