1 Important Notices on Safety
1-6. Information about explosion-proof performance (Overseas explosion-proof spec.)
12 / 87
1-6-4. Notice on safety
WARNING
・
Do not open when an explosive atmosphere is present.
Caution
・
Do not open the cover while in operation.
・
Do not take apart, remodel and change the instrument.
・
Contact the nearest Riken Keiki’s agents or Riken Keiki to perform adjustment, including the gas
calibration, and parts replacement etc.
・
Contact the nearest Riken Keiki’s agents or Riken Keiki if any abnormalities are found.
・
Make sure to perform a regular check.
・
Make sure to use suitable cables.
・
Do not repair the flame-proof composition surface.
・
All bolt with the hexagon socket must use the stainless steel material of property
class "A2-70".
・
The internal and external ground connection shall be made with a cable lug and be
secured by additional means to prevent twisting.
・
At the internal ground connection the cable lug shall be installed between
the washer and the toothed lock washer.
・
Gas conditions
Composition
IIC gases other than H
2
cannot be used.
Max Flow
Measurement gas:1L/min
Reference Gas:0.5L/min
Pressure range
Measurement Gas Reference Gas Out Gas : 80
~
110kPa
Temperature
Measurement Gas Reference Gas Out Gas :-20
~
60
℃
・
In case oxygen presents in the sampling gas which is supplied into OHC-800 and emitted
from OHC-800, contents of oxygen should be lower than that normally present in air.
・
The sampling gas which is supplied into OHC-800 and emitted from OHC-800 should not be within
the explosive limits continuously for long period or frequency.
・
Power on the measuring system after pipings in the enclosure are purged with process gas.
Also, power off the measuring system while pipings in the enclosure are purged with process gas.
・
Periodic maintenance service shall be performed to check if there is no failure of the gas containment.