4. Installation
4-7 Connecting the power and signal cables
66 / 168
5 Pull out the remote connection terminal plate from the
terminal plate board.
6 Unscrew the single M3 screw securing the clamp
and remove the clamp.
7 Connect the power and signal cables extending from the
remote sensor head (GD-3) to the remote connection
terminal plate.
Connect the cables to the following terminals on the remote
connection terminal plate. For information on connecting
cables to the terminal plate, refer to ‘4-7-5 Connecting
cables to the terminal plate’.
Terminal
No.
Power/signal cable connection
1
Power supply (+)
2
Power supply (−)
3
Signal (+)
4
Signal (−)
Recommended shielding length: 30 - 40 mm
Recommended insulation length: 130 - 140 mm
8 Mount the terminal plate on the terminal plate board.
Adjust the cable position so that no load is applied to the
terminal plates.
Sheathing
Conductor
Insulation
Shielding
(The numbers are
terminal numbers.)
Remote connection terminal
plate
1
4
3
2
Screw (M3)
Clamp
Содержание GD-3EC
Страница 28: ...2 Important Safety Information 2 4 Safety information 28 168 Connection examples GD 3RI GD 3ECB SD 3SC SD 3SC...
Страница 169: ...11 Appendix Revision History 169 168...
Страница 170: ...11 Appendix Revision History 170 168...
Страница 171: ...11 Appendix Revision History 171 168...
Страница 172: ...11 Appendix Revision History 172 168...
Страница 173: ...11 Appendix Revision History 173 168...
Страница 174: ...11 Appendix Revision History 174 168...
Страница 175: ...11 Appendix Revision History 175 168...
Страница 176: ...11 Appendix Revision History 176 168...
Страница 177: ...11 Appendix Revision History 177 168...