2. Important Safety Information
2-4 Safety information
25 / 168
<Components that can be connected (SD-3/SD-3SC)>
The following components can be connected to the main unit (SD-3/SD-3SC):
Connector
1
Connector
2
Connector
3
Connector
4
Connector
5
Connector
6
Sensor assembly
×
×
×
×
×
〇
EC barrier
×
×
×
×
×
〇
Approved cable gland
〇
〇
×
〇
×
〇
M25 plug
〇
〇
×
〇
〇
×
Adapter
(M25
⇔
1/2NPT)
〇
〇
×
〇
×
〇
Adapter
(M25
⇔
3/4NPT)
〇
〇
×
〇
×
〇
Adapter
(M25
⇔
M20)
〇
〇
×
〇
×
〇
Lightning arrester
×
〇
×
〇
×
×
〇
: Can be connected
×
: Cannot be connected
NOTE
Connect only components that are compatible with the individual connectors on the main unit (SD-3/SD-
3SC).
Tighten M25 plugs and adapters to a torque of at least 30 Nm.
Secure a minimum thread engagement of five threads.
<Lightning arrester details>
Part
Manufacturer
Eaton Electric Limited
Name/No.
TP48 or TP32 series surge protector
Explosion-proof
performance
II 2G Ex db IIC T6 Gb
Certification
Nos.
No. and issue
IECEx BAS 15.0056X Issue 1, Baseefa 04 ATEX 0053X
Applicable standards
EN 60079-0:2012+A11:2013
EN 60079-1:2014
IEC 60079-0:2011 Edition 6.0
IEC 60079-1:2014 Edition 7.0
Rating
Voltage/current
48 V DC
Temperature*
-40 - +70 °C
Installation
Attachment screw
1/2NPT
*The minimum ambient temperature for the SD-3/GD-3 when using a surge protector is -40 °C.
Содержание GD-3EC
Страница 28: ...2 Important Safety Information 2 4 Safety information 28 168 Connection examples GD 3RI GD 3ECB SD 3SC SD 3SC...
Страница 169: ...11 Appendix Revision History 169 168...
Страница 170: ...11 Appendix Revision History 170 168...
Страница 171: ...11 Appendix Revision History 171 168...
Страница 172: ...11 Appendix Revision History 172 168...
Страница 173: ...11 Appendix Revision History 173 168...
Страница 174: ...11 Appendix Revision History 174 168...
Страница 175: ...11 Appendix Revision History 175 168...
Страница 176: ...11 Appendix Revision History 176 168...
Страница 177: ...11 Appendix Revision History 177 168...