The intermittent (acid) cleaning process works as follows:
Acid is pumped from the tank used for intermittent (acid) cleaning, and is fed
into the wastewater tank. Here it mixes with the wastewater.
The wastewater pump draws the wastewater from the wastewater tank.
The wastewater enters the stack via both valves.
The stack is cleaned.
The wastewater leaves the stack via both valves.
The wastewater flows back into the wastewater tank.
After that, another short flush with fresh water is initiated and the wastewater is
discharged into the sewer.
2.3
Product specifications
The NoNa
+
is available in various configurations, because multiple drain water
groups, ring filters and I/O modules can be added to the NoNa
+
. This is described in
this and the following sections.