Navigate the path:
.
Tap the
Unit capacity
setting. A pop-up menu appears.
Enter the capacity of the NoNa
+
.
Tap the Confirm icon ‘
'.
Tap the
Preset values
setting. A pop-up menu appears.
Select Yes.
Tap the Confirm icon ‘
'.
The NoNa
+
automatically enters the values depending on the capacity of the NoNa
+
.
See the table below for the values entered (and the associated settings).
Setting
Path
Set for capacity (l/min)
5 - 10
10 - 20
20 - 40
Purification cycle time (min)
15
20
30
Flush quantity (litres)
10
15
20
Minimum wastewater flow [l/min]
2.0
5.0
10.0
Maximum wastewater flow [l/min]
12.0
25.0
50.0
Minimum drain water flow [l/min]
2.0
5.0
10.0
Maximum drain water flow [l/min]
12.0
25.0
50.0
Cleaning duration (min)
30
45
60
If you have changed the settings above, you can restore the default values by
changing the
Preset values
setting to 'Yes'.
6.3.3
Purification (sodium removal)
After a short flush with fresh water, the NoNa
+
begins the purification process. The
system supplies current and voltage to the stack and starts removing the sodium from
the drain water. At the same time, the system initiates continuous (acid) cleaning by
circulating the wastewater (to which acid has been added).
The following settings need to be defined for the purification process:
Setting
Use
More
information
Purification
cycle time
This sets the duration of one purification (sodium
removal) cycle. During a cycle, the stack is charged or
discharged. This is an advanced setting.
Minimum
purification
duration
The minimum length of time that a drain water tank will
be used (continuously) for purification.
NoNa
+
56