EXAMPLE
3 x 400 V, 50 Hz
This means that the NoNa
+
10 and 20 will be fitted with a Loware BG 5 pump.
The NoNa
+
40 will be fitted with a Loware BG 7 pump.
2.3.6
Sensors
This section provides a description of the EC sensors.
Figure 2-12:
Figure showing location of EC sensors
No.
Description
No.
Description
1
EC sensor (measurement in drain
water)
2
EC sensor (measurement in purified
water)
The NoNa
+
is supplied with two EC sensors as standard. The first sensor measures the
EC value of the drain water, and the second sensor measures the EC value of the
purified water.
Please consult the supplied OEM manuals for the correct use and maintenance of the
relevant components.
2.3.7
I/O modules
The NoNa
+
uses I/O modules called Smart Switches. Smart Switches are the (manual
control) switches used for the HortiMaX-Go! process controller. These switches are
equipped with an electrical circuit, a processor and software.
The following table below provides an overview of the different types of I/O modules:
Module type
When relevant
Smart Switch Weather/Alarm
Always
Smart Switch EC
Always
NoNa
+
22
Содержание NoNa+
Страница 1: ...SV 2 4 15 05 2020 96000023 Installation and User Manual NoNa...
Страница 49: ...Flow rate settings Capacity NoNa 10 NoNa 20 NoNa 40 Expected wastewater flow 10 l min 20 l min 40 l min NoNa 49...