Common problems and troubleshooting
11.1
Solutions for screen display faults
After powered on the “Screen flicker or automatically restart”
1)
Switching mode power supply is insufficient. Check power supply if there are problems, and
change high-quality power supply to solve the problems.
2)
The local power grid unstable. Check local grid voltage stability or use the regulator filter
device.
3)
The power chip of the handle is ageing. This phenomenon also appears when the handle is
powered through the USB cable to the computer. Please return back the handle to our
company.
4)
Temporary solution. Using standard 5V mobile phone charger, supply power through the
USB cable to handle. Duplicate power supply for temporary emergency use.
Failed to set work piece origin during normal operation process
1)
It is under the mechanical coordinate system. Check if the main interface displays AX AY AZ,
AA, if yes, should press "
" + "
" switching to work coordinate system. Then it
can set work origin. Press "
" + "
" is for going to mechanical coordinate
system where cannot set work origin in there.
2)
The buttons are broken. Go to “SYSTEM SETUP”-“Buttons Check” menu to check whether
the buttons are normal or not.
Assertion error
Assertion error (occurred during the processing or after starting) is generally a software
problem. User can boot the controller by entering “emergency state”, or re-upgrade it. If can’t be
solved either, user should send back it for repairing.