北京锐志天宏科技股份有限公司
Beijing RichAuto S&T Co., Ltd.
13
Forging ahead, create future together!
X08
Driver alarm
Logic low
24V
Output DC 24V
To active sensors
GND
GND
To active sensors
SHIELD
Shielded signal
3.3
Hardware wiring
Installation Requirements: Switching mode power supply
(
24V, 3A
)
, it’s better to add a
filter to prevent the electric field interference. If origin detecting switch is different power supply
type, the special detecting switch power supply is needed. (Recommend 24V origin detecting
switch).
RichAuto
Interface board terminal can be divided into input terminal and output
terminal
:
Input terminal
:
INPUT SIGNAL terminal; Main power supply terminal.
Output terminal
:
X,Y,Z,C axis pulse signal output terminal; OUTPUT SIGNAL terminal.
3.3.1
Input terminals
Main power supply wiring:
INPUT SIGNAL wiring
1)
ZERO point (HOME):
X, Y Z axis wiring methods are the same
Mechanical switch NPN normally open proximity switch