Press “spindle on” button, but spindle does not start
1)
Check wiring, if normal, check if the inverter has alarm, if the inverter is normal and its
setting is correct, and then check if the spindle motor damaged or not.
2)
Check if 50-pin cable is loose. Confirm the settings of inverter refer to its manual to debug
one by one.
3)
Check interface board. Press“
” to start spindle, use multimeter to measure Y1 and
GND to see whether conducting, if not, interface board or 50-pin cable is broken. To replace
a new one for trouble clearing one by one.