6. Troubleshooting (Action in Case of an Error)
R20UT3587EJ0302 Rev.3.02
Page 217 of 232
Sep.01. 21
(2) Configuration Properties Dialog Box Does Not Appear in Booting-up of the Emulator Debugger
Table 6.2 Points to check for errors in booting-up of the emulator debugger (1)
Error
Point to check
Communication initialize error
Check all emulator debugger settings and the connection of the interface
cable.
See “4. Preparation for Debug” (page 69).
A communication error.
(3) Error Occurs in the Connecting Dialog Box
Table 6.3 Points to check for errors in booting-up of the emulator debugger (2)
Error
Point to check
MCU board is not connected.
Re-check the connection between the E100 and the MCU unit.
See “2.3 Connecting the MCU Unit to and Disconnecting it from the
E100 Emulator Main Unit” (page 28).
The system configuration of the E100 emulator
is not corresponding to the content of the
E100.ENV file.
The combination between the emulator software and the MCU unit is not
correct. Refer to the release notes of the emulator software, and confirm
the combination between the emulator software and the MCU unit.
A timeout error. The MCU is in the reset state.
Is system reset issued?
Check the oscillation of the oscillator module mounted on the MCU unit,
and confirm that the oscillator module is properly mounted.
A timeout error. The MCU's internal clock is
halted. Is system reset issued?
A timeout error. No clock signal is supplied to
the MCU. Is system reset issued?
A timeout error. The power supply to the MCU
is off. Is system reset issued?
Check that power is being correctly supplied to the user system and that
the user system is properly grounded.
(4) Errors Occur in booting-up of the emulator debugger
Table 6.4 Points to check for errors in booting-up of the emulator debugger (3)
Error
Point to check
A timeout error.
(1) Check that the NQPACK etc. mounted on the user system is
soldered properly.
(2) Check that the connector is installed properly to the user system.