5.9.8
Viewing Trace Results
To check trace results, open the Trace window. Trace results can be shown in one of the following display modes: bus,
disassembly, source, or mixed. The display can be switched by changing the selection of Display Mode in the popup menu of
the Trace window.
(1) Bus Display Mode
In the popup menu, select Display Mode -> BUS. Bus information is displayed for all traced cycles (this is the default display
mode).
Figure 5.57 Trace window