R0E417250MCU00 User
’s Manual
R20UT3587EJ0302 Rev.3.02
Page 135 of 232
Sep.01. 21
(3) Other conditions
You can select one from among five available choices: AND (cumulative), AND (simultaneous), Subroutine, Sequential and
State transitions. To set any condition, select the checkbox to the left of “Other conditions.”
Other conditions are disabled by default (the checkbox to the left of “Other conditions” is not selected). Cumulative AND is
listed as “AND(Accumulation)” in the dialog box.
Figure 5.52 Trace conditions dialog box
Table 5.21 Other conditions
Type
Description
AND (cumulative)
A trace point is encountered when all of the specified events have occurred, regardless of the
timing.
AND (simultaneous)
A trace point is encountered when all of the specified events occur at the same time.
Subroutine
A trace point is encountered when a specified event occurs within a specified address range
(subroutine or function).
Sequential
6 steps (forward direction) + reset point
A trace point is encountered when the specified events occur in a specified order.
State transitions
3 steps, 9 paths + reset point
A trace point is encountered when the specified events occur in a specified order.
CAUTION
When a time-out condition is set in State transitions (Trace) dialog box, the time to make transition from a set state to another
then back to the original set state must be 10 µs or more. Transition time of less than 10 µs will result in an incorrect timeout
detection.