Selecting the Trace Mode
(1) Selecting the trace mode
The following five trace modes are available.
Table 5.14 Trace modes
Trace mode
Description
Fill until stop
Trace acquisition continues until the program stops running.
Fill until full
Trace acquisition stops when the trace memory becomes
full.
Fill around TP
Trace acquisition stops a specified number of cycles after a
trace point is encountered. A delay value can be specified in
the range up to the maximum value of trace capacity.
Repeat fill until stop
For each trace point encountered in program execution,
information for a total of 512 cycles* before and after the
point is acquired, and acquisition continues in the same way
until the program stops running.
Repeat fill until full
For each trace point encountered in program execution,
information for a total of 512 cycles* before and after the
point is acquired, and acquisition continues in the same way
until the trace memory is full.
CAUTION
*Recording is for 512-cycles units, consisting of the lines for the cycle at the trace point, for the 255 cycles before that point,
and for the 256 cycles after that point.
Figure 5.49 Differences between the trace modes