R0E417250MCU00 User
’s Manual
R20UT3587EJ0302 Rev.3.02
Page 192 of 232
Sep.01. 21
3. The Violation of access protection dialog box shown below will be displayed.
To have the access attributes automatically set according to the section information in the downloaded module when a
program is downloaded, select the checkbox labeled “Automatically set address areas at downloading.”
Figure 5.110 Violation of access protection dialog box
4. Click on the Update button, and the access attributes will be updated according to the section information in the downloaded
module.
5. To add an access attribute manually, click the Add button. The Access protection condition dialog box shown below will
appear. Specify any address range and access attribute.
Figure 5.111 Access protection condition dialog box