Maintenance instructions
21
102-127108955
V1.1
92/ 102
Maintenance instructions
The following points must be checked:
Base fixing
Is the DFA 127 securely fixed to the backing construction?
Chassis
Is the attachment still normal?
Door hinge
Can the door leaf be moved smoothly?
Gearbox
Function lubricate for grease spreading in gearbox
▪ remove arm from operator
▪ set operator on mode Manual
▪ actuate function by FPC 902 or BDE-D
▪ The motor performs a few rotations and the lubricating grease is
spread in the gearbox.
▪ Subsequently, connect the arm again to the operator.
Arm
Has the fixing screw of the arm been firmly tightened? Torque: 28 Nm
In case of high stress on the arm, the screw can additionally be secured
with Loctite 243.
Function
Does the movement of the door give reason for dissatisfaction?
Wiring
Are all the cables connected and have the clamping screws been firmly
tightened?
Are all connection assemblies to the motor in order?
Calibration run
Initiation of a new calibration run
Control unit
Check the function of all modes of operation
Actuating devices
Function test of motion sensors, push button, pull-switch etc.
Safety elements
Function test of safety cells on door leaves (SIO/SIS).
Safety functions
Examine the external connections (EMERGENCY STOP / SSK).
Electrical door lock
Function test of electrical door lock and monitoring
Casing
Are the casing and the side cover plates properly installed?
21
Содержание DFA 127
Страница 31: ...Assembly dimension diagrams 10 102 127108955 V1 1 31 102 Dimension diagram 2 for standard arms 10 2 ...
Страница 98: ...Drawings 25 102 127108955 V1 1 98 102 Drawings Cable layout 25 25 1 ...
Страница 99: ...Drawings 25 102 127108955 V1 1 99 102 ...
Страница 100: ...Drawings 25 102 127108955 V1 1 100 102 Wiring diagram 25 2 ...
Страница 101: ...Drawings 25 102 127108955 V1 1 101 102 ...
Страница 102: ...Drawings 25 102 127108955 V1 1 102 102 ...