Construction and Function
5
102-127108955
V1.1
23/ 102
Construction and Function
Construction
Key:
1
Mains connection terminals
9
Slide switch in rotation direction
2
Fine-wire fuse
10
Multifunctional switch on STG
3
NET power supply
11
Closing spring
4
ATM drive unit
12
Vision panel, adjust. spring tension
5
STG control unit
13
Adjusting screw for spring tension
6
STG connection terminals
14
Connectors for arms (both sides)
7
Motor print MOT
15
Standard switch BDI
8
ATE drive unit terminals
16
Status signal and Reset button
Functions
The record DFA 127 has been designed to close without electrical power. It can be easily
opened by hand and closes using the energy stored in the spring, with the motion damped
by the motor acting as a generator.
If the door operator is connected to the mains power, the opening and closing movements
will be assisted by the motor.
The following functions are provided exclusively for the safety of the user:
Collision detection: If the door strikes an obstacle while opening, it stops immediately and
stores the position of the impact. During the time delay, the drive briefly tries to reach the
open position. Once the time delay has expired, the door closes, and, when next opened,
the door passes the impact position very carefully in slow mode. This prevents a further vio-
lent impact.
Reversing:If the door strikes an obstacle when closing, it is reopened immediately.
5
5.1
5.2
Содержание DFA 127
Страница 31: ...Assembly dimension diagrams 10 102 127108955 V1 1 31 102 Dimension diagram 2 for standard arms 10 2 ...
Страница 98: ...Drawings 25 102 127108955 V1 1 98 102 Drawings Cable layout 25 25 1 ...
Страница 99: ...Drawings 25 102 127108955 V1 1 99 102 ...
Страница 100: ...Drawings 25 102 127108955 V1 1 100 102 Wiring diagram 25 2 ...
Страница 101: ...Drawings 25 102 127108955 V1 1 101 102 ...
Страница 102: ...Drawings 25 102 127108955 V1 1 102 102 ...