Installation DFA 127
11
102-127108955
V1.1
38/ 102
Checking the mechanical functions
▪ Are the arms fixed at the correct angle to the door leaf?
▪ When moved by hand, does the door leaf move easily over its full swing?
▪ Does the operator damp the opening by spring force? If not, the slide switch position S1
on the motor print MOT must be changed.
The switch position is set according to the direc-
tion of rotation of the arm while opening.
If, for example, the standard arm moves away to
the right when opening, the slide switch must be
set to the right.
WARNING
Unexpected slamming of the door
• Contusions, bruises or cutting off of extremities through door leaves
Check position of slide switch. If the door closes, the mouvement has to be
attenuated. The door should not slam shut.
▪ Does the DFA work as mechanical door closer?
▪ With slide arms: Acceleration before definite closing visible.
Control unit STG 127
The control unit works with an active HIGH level. To activate the function, +24V must be
present. Safety inputs will be activated by an interruption. The basic signal 0V is connected
to the protective earth. This connection can be interrupted for test reasons by use of the
„ground screw“, located next to terminal 1.
NOTICE
The STM 127 control module has been tested according ISO standard 13849-
1:2006, category 2 PL c.
11.5
11.6
Содержание DFA 127
Страница 31: ...Assembly dimension diagrams 10 102 127108955 V1 1 31 102 Dimension diagram 2 for standard arms 10 2 ...
Страница 98: ...Drawings 25 102 127108955 V1 1 98 102 Drawings Cable layout 25 25 1 ...
Страница 99: ...Drawings 25 102 127108955 V1 1 99 102 ...
Страница 100: ...Drawings 25 102 127108955 V1 1 100 102 Wiring diagram 25 2 ...
Страница 101: ...Drawings 25 102 127108955 V1 1 101 102 ...
Страница 102: ...Drawings 25 102 127108955 V1 1 102 102 ...