Configurations
16
102-127108955
V1.1
62/ 102
TIME DELAYS OPEN
21..40 = 22 to 60 seconds, 2 s increments
▪ The hold-open time starts only after all trigger and
safety signals have been made in the closing direc-
tion.
→ Time delay SSK
4 Determines the minimum time for which a door stays open
after it has been opened by a type SSK triggering signal.
0..20 = 0 to 20 seconds, 1 s increments
21..40 = 22 to 60 seconds, 2 s increments
▪ The hold-open time starts only after all trigger and
safety signals have been made in the closing direc-
tion.
NOTICE
The open duration can be reduced when sensors are used which keep the door
open, for example,
Time delay with record sensors.
DRIVE
→ Opening angle
35 The opening angle is read during the learning cycle and corre-
sponds to the value 40.
0 = minimum opening angle
40 = maximum opening angle
▪ DIN: min. 95°
→ Collision CLOSED
20 Reaction point for collision detection during closing of the door.
0 = smooth
40 = rough
▪ The kinetic energy of the moving door is partially ab-
sorbed by the obstacle. According to its characteris-
tics, it takes a certain time for the controller to notice
the increase in force and reopen the door.
→ Collision OPEN
20 Reaction point for a collision detection during opening run (se-
condary closing edge).
0 = smooth
40 = rough
▪ The kinetic energy of the moving door is partially ab-
sorbed by the obstacle. According to its characteris-
tics, it takes a certain time for the controller to notice
the increase in force and stop the door.
Содержание DFA 127
Страница 31: ...Assembly dimension diagrams 10 102 127108955 V1 1 31 102 Dimension diagram 2 for standard arms 10 2 ...
Страница 98: ...Drawings 25 102 127108955 V1 1 98 102 Drawings Cable layout 25 25 1 ...
Страница 99: ...Drawings 25 102 127108955 V1 1 99 102 ...
Страница 100: ...Drawings 25 102 127108955 V1 1 100 102 Wiring diagram 25 2 ...
Страница 101: ...Drawings 25 102 127108955 V1 1 101 102 ...
Страница 102: ...Drawings 25 102 127108955 V1 1 102 102 ...