Configurations
16
102-127108955
V1.1
70/ 102
When closing, the moving leaf waits until the stationary leaf is
closed.
▪ With low door thickness and slight overlap, the value
of 2 can be adjusted to achieve a continuous closing
process.
→ Opening sequence
5 Delayed approach to stationary leaf.
0 = no delay
40 = max. delay (moving leaf opens completely)
→ Closing sequence
20 Delayed closure of the moving leaf.
0 = no delay
40 = max. delay (stationary wing closes completely)
NOTICE
All controls to 0 = synchronous mode.
Opening or closing sequence to 40: The following door leaf waits until the first
door leaf is fully open or fully closed. With these settings, the overlap has the
highest priority.
MANUAL MODE
→ When closing
The parameter defines how the door is to react in the operat-
ing mode
‘Manual’ .
▪ With low-energy applications the door closes in ‘Ma-
nual mode’.
→ Disabled
X The door closes with motor drive and programmed closing
speed.
→ Active
The door closes with motor drive controlled only by spring
tension.
▪ When using drives on fire-resistant doors the closing
time for the event of a power failure or a drive failure,
according to the table in the chapter Fire Protection
Specification, must be set by means of jumper J5 to
motorprint MOT.
Содержание DFA 127
Страница 31: ...Assembly dimension diagrams 10 102 127108955 V1 1 31 102 Dimension diagram 2 for standard arms 10 2 ...
Страница 98: ...Drawings 25 102 127108955 V1 1 98 102 Drawings Cable layout 25 25 1 ...
Страница 99: ...Drawings 25 102 127108955 V1 1 99 102 ...
Страница 100: ...Drawings 25 102 127108955 V1 1 100 102 Wiring diagram 25 2 ...
Страница 101: ...Drawings 25 102 127108955 V1 1 101 102 ...
Страница 102: ...Drawings 25 102 127108955 V1 1 102 102 ...