background image

608 Series

Heavy Duty Switch Bollard 

INSTALLATION INSTRUCTIONS

8701 Castle Park Drive 

 Indianapolis, Indiana 46256

Telephone: (800) 842-2545/(317) 842-2545 

 www.mssedco.com 

 [email protected]

Page 1

(/MANU)  608v0808

SURFACE MOUNT INSTALLATION

IN GROUND INSTALLATION

FIGURE 1a

FIGURE 1b

Section 1

General Description

The 608 Series switch bollard is designed to provide a 
freestanding, self-contained automatic door activation 
device that can be installed at any location.  While 
numerous options are available from the factory, this 
manual covers installation steps for our most common 
versions.

Section 2

Basic Installation

SURFACE MOUNT INSTALLATION WITH INTERNAL SHOE 

(see Figure 1a)

1)  Drill concrete for two 3/8" x 3" anchor bolts provided 
 

using the mounting shoe as a template. 

2)  Place plastic rust shield provided over holes in the 
 

concrete, set mounting shoe onto the rust shield.

 

NOTE:

 If bollard switch is to be hardwired, pull 

 

conduit through holes in the center of the rust 

 

shield and mounting shoe.  Pull electrical wires 

 

long enough to be accessible from the top of the 

 

bollard once mounted (approximately 42”).

3)  Hammer anchor bolts into holes in concrete 
 

shimming as necessary to level bollard.  Securely 

 

tighten anchor bolts.

4)  Slide bollard over mounting shoe and secure with the 
 

four 1/4"-20 x 1/2" bolts provided.  Caulk around 

 

base of bollard as needed.

PROCEED TO SECTION 3-WIRING

SURFACE MOUNT INSTALLATION WITH EXTERNAL SHOE 

(see Figure 1b)

1)  Drill concrete for four 5/16” x 2 1/2” power bolts 
 

provided using the mounting shoe as a template. 

2)  Place plastic rust shield provided over holes in the 
 

concrete, set bollard onto the rust shield.

 

NOTE:

 If bollard switch is to be hardwired, pull 

 

conduit through holes in the center of the rust 

 

shield and mounting shoe.  Pull electrical wires 

 

to top of bollard so they are accessible.

3)  Hammer power bolts into holes in concrete 
 

shimming as necessary to level bollard.  Securely 

 

tighten power bolts.

4)  Caulk around base of bollard as needed.
PROCEED TO SECTION 3-WIRING

IN-GROUND MOUNT INSTALLATION (see Figure 1c)

1)  Core a 3” diameter hole in the concrete 12” deep.  If  
 

no concrete exists, dig a hole 12” deep.

2)  Secure the in-ground mounting shoe to the bollard 
 

with the four 1/4-20 x 1/2" bolts provided.

3)  Place the entire bollard assembly into prepared hole. 

 

NOTE:

 If bollard switch is to be hardwired, pull 

 

conduit through hole in the center of the 

 

mounting shoe.  Pull electrical wires to top of 

 

bollard so they are accessible.

4)  Pour concrete into hole.
5)  Push bollard further into the hole until base is at 
 proper 

height.

6)  Level and brace bollard. 
7)  Once all concrete has cured, caulk around base of 
 

bollard as needed.

PROCEED TO SECTION 3-WIRING

!

!

!

5"

5"

GROUND LEVEL

L

1/4-20 x 1/2” Bolt

MOUNTING

SURFACE

RUST SHIELD

3/8" x 3" ANCHOR

BOLTS & BRACKET

1/4-20 x 1/2” Bolt

MOUNTING

SURFACE

RUST SHIELD

5/16” x 2 1/2”
Power Bolts

9“ SQUARE 

WELDED FOOT

FIGURE 1c