MS Sedco 608 Series Скачать руководство пользователя страница 2

608 Series

Heavy Duty Switch Bollard 

INSTALLATION INSTRUCTIONS

8701 Castle Park Drive 

 Indianapolis, Indiana 46256

Telephone: (800) 842-2545/(317) 842-2545 

 www.mssedco.com 

 [email protected]

Page 2

(/MANU)  608v0808

PLASTIC CAP

TRANSMITTER AND
SPACER PLATFORM

PRESS

9V

PCB

300MHz

390MHz

HDRC™

FREQUENCY SELECTION 

SWITCH

  1 2 3 4 5 6 7 8 9 10 

11 

12

O
N

12 POSITION SECURITY 

CODE SWITCH

ClearPath

HDRC™ Program 1-12

300 MHz Program 1-10
390 MHz Program 1-12

BATTERY HARNESS

Section 3

Wiring

HARDWIRED

1)  Connect the two signal wires to the appropriate contacts on the switch.  (Standard connections are COM and N.O.)
2)  Set the spacer platform (provided) in the top of the switch bollard opposite to the cap mounting holes.
3)  Install the cap and fasten with the two 8-32 x 1/2" screws provided.  

 

NOTE:

 Two signal wires are required per switch on vestibule models. 

RADIO CONTROL (WIRELESS)

When a ClearPath radio transmitter option is ordered from the factory, the 608 series bollard will come complete with 
the transmitter and battery mounted on its platform ready to be installed under the plastic cap.  The CP/TX-P, CP/STX-P 
(vestibule sequencing version), and CP/TX-VP (2 transmitters) feature 3 selectable frequencies in a single device: High 
Definition Radio Control™ (HDRC™), 300 MHz and 390 MHz.
1)  SELECT FREQUENCY:  Select the desired frequency, via the 3-position slide switch on the transmitter circuit board 
 

(Fig. 1).  HDRC™ is factory setting.

 

FIGURE 1

2)  SELECT SECURITY CODE:  Program the desired security code, via the 12 dip 
 

switches on the transmitter circuit board (Fig. 1).

  
 

NOTE:

 For sequencing transmitters refer to CP/STX-P installation 

 

instructions for proper programming.

3)  Plug the 2-lead transmitter wiring harness onto the "COM" (Common) 
 

and "N.O." (Normally Open) contacts located on the door activator's 

 microswitch.
4)  Set transmitter platform in the top of bollard opposite to the cap screw holes. 
5)  Install the cap and secure it with the two 8-32 screws provided.

 

NOTE:

 Vestibule switch bollards are supplied with two transmitters 

 

(one per switch).

 

NOTICE:    

This device complies with Part 15 of the FCC

 

rules.  Operation of this device is subject to the  

 

following two conditions: 1) This device may not

 

cause harmful interference and 2) This device

 

must accept any interference received, including

 

interference that may cause undesired operation.

 

Any changes or modifications not expressly 

 

approved by MS SEDCO could void the user’s

 

authority to operate this equipment. 

!

!

!

!

HDRC™:

 MS SEDCO proprietary technology

300 MHz:

 Compatible with Multicode™ products

390 MHz:

 Compatible with MS SEDCO and GENIE™ products

MICROSWITCH ASSEMBLY

ClearPath

MICRO-SWITCH

UL LISTED
SPDT, Momentary
RATED: 15A @ 125V A C

COM

N.C.

N.O.

Rubber Bellows

Insert rubber bellows 
over spring on 
exterior switches for 
weather tight fit!