Accessories
19
102-127108955
V1.1
89/ 102
Extended function module FEM 1
Nameplate, connections and controls FEM 1
Mounting kit FEM 1 with 1 m cable
FEM 1 module
102-020809040
102-020809033
Place and install the FEM 1 directly beside the control unit.
IMPORTANT
For reasons of space the extended version should always use at least 780 mm
drive length.
Chassis 85 mm
(only possible on extended side)
Chassis 108 mm
(possible left or right)
4 potential-free inputs
Principle:
Terminal connections:
+24V:: 64/66/68/70
O V: 65/67/69/71
14 relay outputs
Principle:
Closing function
Opening function
Terminal connections:
73/76/79/82
88/90/92/94/96/98/100
102/104/106
74/77/80/83
89/91/93/95/97/99/101
103/105/107
▪ Relay with two-way contact 24V / 1A
▪ Function (opening/closing contact) with selectable jumper
19.2
Содержание DFA 127
Страница 31: ...Assembly dimension diagrams 10 102 127108955 V1 1 31 102 Dimension diagram 2 for standard arms 10 2 ...
Страница 98: ...Drawings 25 102 127108955 V1 1 98 102 Drawings Cable layout 25 25 1 ...
Страница 99: ...Drawings 25 102 127108955 V1 1 99 102 ...
Страница 100: ...Drawings 25 102 127108955 V1 1 100 102 Wiring diagram 25 2 ...
Страница 101: ...Drawings 25 102 127108955 V1 1 101 102 ...
Страница 102: ...Drawings 25 102 127108955 V1 1 102 102 ...