Configurations
16
102-127108955
V1.1
81/ 102
Function chart:
Mechanical BDE (external BDE)
MS BDE-M (102-016841000)
BDE2 / clamp 2
BDE1 / clamp 1
Function
L
L
locked
L
H
continuously open
H
H
manual
H
L
automatic
Toggle switch BDI on the side cover or external
BDE2 / clamp 2
BDE1 / clamp 1
Function if the external
mech. BDE is not con-
figured
Function if the external
mech. BDE will be con-
figured
L
H
continuously open
continuously open
H
L
manual
automatic
L
L
automatic
locked
(L = interruption or 0 V, H = +24 V)
Connection of a time switch for "locked" (SUR-V)
*
Contact closed
=
mode of operation according to the position of
the operation switch
Contact open
=
Mode of operation
Locked
NOTICE
In combination with a BDE-D control unit, it is recommended to activate the con-
trol lock of the BDE-D ( or
).
Otherwise, the door can no longer be unlocked using an external mechanical
BDE-M or external signals to the BDI-M circuit board after selection of the
Lo-
cked operating mode if it has been locked in the meantime with the BDE-D!
16.3.1
16.4
Содержание DFA 127
Страница 31: ...Assembly dimension diagrams 10 102 127108955 V1 1 31 102 Dimension diagram 2 for standard arms 10 2 ...
Страница 98: ...Drawings 25 102 127108955 V1 1 98 102 Drawings Cable layout 25 25 1 ...
Страница 99: ...Drawings 25 102 127108955 V1 1 99 102 ...
Страница 100: ...Drawings 25 102 127108955 V1 1 100 102 Wiring diagram 25 2 ...
Страница 101: ...Drawings 25 102 127108955 V1 1 101 102 ...
Страница 102: ...Drawings 25 102 127108955 V1 1 102 102 ...