Commissioning DFA 127
13
102-127108955
V1.1
45/ 102
The CAN-Bus
The bus topology
IMPORTANT
Every bus component has two plug connections, which must both be plugged for
correct wiring.
The bus must basically be terminated at both ends with a terminating resistance
(120 Ω).
IMPORTANT
Make sure that no CAN sockets are left unplugged. Either all sockets are used or
they will be plugged witha terminating resistor.
NOTICE
The BDE-D is always delivered with a terminating resistor connected to it.
The second terminating resistor is located in STM (Jumper J8)
General Bus structure
Installation with 2 motion sensors
13.2
13.2.1
Содержание DFA 127
Страница 31: ...Assembly dimension diagrams 10 102 127108955 V1 1 31 102 Dimension diagram 2 for standard arms 10 2 ...
Страница 98: ...Drawings 25 102 127108955 V1 1 98 102 Drawings Cable layout 25 25 1 ...
Страница 99: ...Drawings 25 102 127108955 V1 1 99 102 ...
Страница 100: ...Drawings 25 102 127108955 V1 1 100 102 Wiring diagram 25 2 ...
Страница 101: ...Drawings 25 102 127108955 V1 1 101 102 ...
Страница 102: ...Drawings 25 102 127108955 V1 1 102 102 ...