Operating modes and behaviour of the door during input signals
Table of signals (X marks a release reaction)
Explanation of the abbreviations see chapter
Abbreviations
Automatic /
AUTO
Normal operation. The door opens and closes automatically, either by triggering of an activa-
tion device or by pushing the door, if the "touch control (push to activate)" is active.
CLOSED
OPENING
OPEN
CLOSING
AKI
X
X
X
X
AKA
X
X
X
X
SSK
X
X
X
X
SIO
X
X
X
SIS
X
X
TIPP
X
Manual operation /
HAND
In this mode the operator works as a normal door closer. It is easy to open the door by hand
and closes automatically. The actuating devices connected are ignored.
One-Way traffic /
EXIT
In the One-Way traffic mode, people cannot enter the room from the outside, but can leave it
from the inside.
CLOSED
OPENING
OPEN
CLOSING
AKI
X
X
X
X
AKA*
X
X
X
SSK
X
X
X
X
SIO
X
X
X
SIS
X
X
TIPP
* AKA is active as safety device while closing
Continuously open /
OPEN
The door is opened and stays open. If an obstruction stands in the way while opening, the
operator tries another five times whithin a few seconds to bring the door to the target posi-
tion. Should the obstruction remain, the current position is then validated as the continuously
open position.
14.2.2
Содержание DFA 127
Страница 31: ...Assembly dimension diagrams 10 102 127108955 V1 1 31 102 Dimension diagram 2 for standard arms 10 2 ...
Страница 98: ...Drawings 25 102 127108955 V1 1 98 102 Drawings Cable layout 25 25 1 ...
Страница 99: ...Drawings 25 102 127108955 V1 1 99 102 ...
Страница 100: ...Drawings 25 102 127108955 V1 1 100 102 Wiring diagram 25 2 ...
Страница 101: ...Drawings 25 102 127108955 V1 1 101 102 ...
Страница 102: ...Drawings 25 102 127108955 V1 1 102 102 ...