- After entering all the required measures, you can spin
the wheel by pressing the button
and closing
the protective guard.
14.3 Indicative display of points where to
detect measures/to fit weight
IT IS VERY IMPORTANT TO RE-
MEMBER THE POINTS SELECTED
FOR MEASUREMENT INSIDE THE
RIM SINCE DURING THE WEIGHTS
FITTING AT “6 O’CLOCK” (WITH
OR WITHOUT FIXED LASER),
THERE ARE NO DIFFERENCES,
EXCEPT FOR A TRANSVERSAL
LINE ON THE RIM, PRODUCED BY
THE FIXED LASER ITSELF, IF ANY.
HOWEVER THE POSITIONING IN
DEPTH WILL BE AT THE DISCRE-
TION OF THE OPERATOR.
Depending on the type of program selected,the machine
shows on the monitor the guideline points where to
take measures and, consequently, where you must
apply weights (
Fig. 58 ref. 4-5
).
2
5
1
6
5
3
4
7
Fig. 58
KEY
1 – 1
st
weight fitting point distance
2 – Rim diameter
3 – Balancing mode
4 – Point at which to take the measure/adhesive
weight fitting
5 – Point at which to take the measure/clip weight
fitting
6 – Last unbalance detected by the machine
7 – Rim width
THE MORE THE POINTS CHOSEN
FOR THE PROBING ARE DISTANT
FROM EACH OTHER THE MORE
THE BALANCING WILL BE EFFEC-
TIVE.
1297-M005-03
RAVAGLIOLI S.p.A.
G4.140R - G4.140WS - G4.140WSLB - GP4.140WS