Remote Control Commands
R&S
®
NRX
247
User Manual 1178.5566.02 ─ 07
DISPlay[:WINDow<Window>]:TRACe:MARKer<Undef>:SELection
<markerNo>
Shows the selected marker in the trace.
Suffix:
<Window>
.
1 to 4
Measurement pane
<Undef>
1 to n
No suffix required.
Parameters:
<markerNo>
NONE | M1 | M2 | M3 | M4
*RST:
NONE
Manual operation:
See
13.5.8
Pulse Analysis
Further information:
●
[SENSe<Sensor>:]TRACe:MEASurement[:STATe]
............................................................ 248
[SENSe<Sensor>:]TRACe:MEASurement:AUTO[:STATe]
...................................................248
[SENSe<Sensor>:]TRACe:MEASurement:OFFSet:TIME
................................................... 249
[SENSe<Sensor>:]TRACe:MID:OFFSet:TIME
...................................................................249
[SENSe<Sensor>:]TRACe:MID:TIME
...............................................................................249
CALCulate<Measurement>:TRACe:MEASurement:ALGorithm
........................................... 250
CALCulate<Measurement>:TRACe:MEASurement:DEFine:DURation:REFerence
CALCulate<Measurement>:TRACe:MEASurement:DEFine:TRANsition:HREFerence
CALCulate<Measurement>:TRACe:MEASurement:DEFine:TRANsition:LREFerence
CALCulate<Measurement>:TRACe:MEASurement:POWer:AVG?
.......................................251
CALCulate<Measurement>:TRACe:MEASurement:POWer:HREFerence?
...........................251
CALCulate<Measurement>:TRACe:MEASurement:POWer:LREFerence?
........................... 252
CALCulate<Measurement>:TRACe:MEASurement:POWer:MAX?
...................................... 252
CALCulate<Measurement>:TRACe:MEASurement:POWer:MIN?
....................................... 252
CALCulate<Measurement>:TRACe:MEASurement:POWer:PULSe:BASE?
CALCulate<Measurement>:TRACe:MEASurement:POWer:PULSe:TOP?
............................253
CALCulate<Measurement>:TRACe:MEASurement:POWer:REFerence?
............................. 253
CALCulate<Measurement>:TRACe:MEASurement:PULSe:DCYCle?
.................................. 253
CALCulate<Measurement>:TRACe:MEASurement:PULSe:DURation?
................................253
CALCulate<Measurement>:TRACe:MEASurement:PULSe:PERiod?
...................................254
CALCulate<Measurement>:TRACe:MEASurement:PULSe:SEParation?
............................. 254
CALCulate<Measurement>:TRACe:MEASurement:TRANsition:NEGative:DURation?
CALCulate<Measurement>:TRACe:MEASurement:TRANsition:NEGative:OCCurrence?
CALCulate<Measurement>:TRACe:MEASurement:TRANsition:NEGative:OVERshoot?
CALCulate<Measurement>:TRACe:MEASurement:TRANsition:POSitive:DURation?
CALCulate<Measurement>:TRACe:MEASurement:TRANsition:POSitive:OCCurrence?
CALCulate<Measurement>:TRACe:MEASurement:TRANsition:POSitive:OVERshoot?
CALCulate<Measurement>:TRACe:MEASurement:TRANsition:SPERiod?
.......................... 256
DISPlay[:WINDow<Window>]:TRACe:MEASurement:POWer:AVG[:STATe]
Measurement Settings and Results
www.allice.de
Allice Messtechnik GmbH