Remote Control Commands
R&S
®
NRX
242
User Manual 1178.5566.02 ─ 07
<Marker>
1 to 4
Marker (M1 to M4)
Parameters:
<function>
POWer | RPOWer | RTIMe | RPAVerage
POWer
Measures the power of the trace.
RPOWer
Measures the power ratio in relation to the reference marker.
RTIMe
Measures the time difference in relation to the reference marker.
RPAVerage
Measures the average power between time positions of the
marker and its reference marker.
*RST:
POWer
Manual operation:
DISPlay[:WINDow<Window>]:TRACe:MARKer<Marker>:MODE
<mode>
Enables or disables the marker. Also defines the appearance of the marker.
Suffix:
<Window>
.
1 to 4
Measurement pane
<Marker>
1 to 4
Marker (M1 to M4)
Parameters:
<mode>
OFF | RULer | MEASure
OFF
Disables the marker.
RULer
Shows a line at the marker position. Useful if you use the marker
as reference marker,
DISPlay[:WINDow<Window>]:TRACe:
MEASure
Shows a triangle at the marker position.
*RST:
OFF
Manual operation:
DISPlay[:WINDow<Window>]:TRACe:MARKer<Marker>:POSition:MODE
<mode>
Defines where the marker is placed.
Suffix:
<Window>
.
1 to 4
Measurement pane
Measurement Settings and Results
www.allice.de
Allice Messtechnik GmbH