Measurement and Result Displays
R&S
®
FSV/A3000 I/Q
Analyzer
14
User Manual 1178.8536.02 ─ 01
Remote command:
LAY:ADD:WIND? '1',RIGH,FREQ
, see
Results:
I/Q-Vector
Displays the captured samples in an I/Q-plot. The samples are connected by a line.
Note:
For the I/Q vector result display, the number of I/Q samples to record ( "Record
Length" ) must be identical to the number of trace points to be displayed ("Sweep
Points"; for I/Q Analyzer: 10001). For record lengths outside the valid range of sweep
points the diagram does not show valid results.
Remote command:
LAY:ADD:WIND? '1',RIGH,VECT
, see
Results: