57
ESPLXD-ET Controller
b
l
The Holding current is typically 10 mA or less. A reading of 50 mA or
greater typically indicates a shorted decoder output.
Ping Sensor Decoder
b
g
Turn the controller dial to Test All stations/Check System.
A
The System Diagnostics screen appears. Press the Down Arrow
button to select 2-Wire Diagnostics; then press Next.
B
The 2-Wire Diagnostics screen appears. Press the Down Arrow
button to select Ping Decoders; then press Next.
1
2
C
The Ping Decoder screen appears. Press the Down Arrow button
to select Sensor Decoder; then press Next.
D
The Ping Sensor Decoder screen appears. Press the + and –
buttons to select the desired Sensor; then press Ping.
3
4
E
The controller will ping the selected sensor decoder and report
the D-Level and Reading. Typically these will show as OK. If a Not
OK reading is reported, check the connections to that sensor
decoder or replace it.
5
ESPLXD-ET user-manual (670504-01) artwork_120716.indb 57
7/16/2012 3:48:20 PM