143
ESPLXD-ET Controller
NOMV Cycling
Since Normally Open Master Valves (NOMVs) are always open, it’s
sometimes helpful to cycle them closed for a minute in order to
maintain the continuity of your valve diaphragms and solenoids. The
controller can be programmed to perform this task automatically.
b
b
NOTE:
Each NOMV will be cycled closed for 60 seconds on the
first day of each month. Since irrigation is suspended when the
NOMV is shut, choose a time when irrigation is not scheduled for
this operation.
b
g
Turn the controller dial to Special Features.
A
The Special Features screen appears. Press the Down Arrow
button to select NOMV Cycling; then press Next.
B
A confirmation screen appears; press Next when ready.
1
2
C
The NOMV Cycling screen appears. Press the + and – buttons to
set the desired time for cycling to start; then press Next.
b
l
Press and HOLD buttons to accelerate settings for hours and
minutes.
D
Press the Yes button to allow cycling to start for each MV or press
No to prevent cycling from starting; then press Next.
3
4
E
Press the Next and Back buttons to navigate through the MVs and
repeat the selection process as desired.
5
b
b
NOTE:
There is no need to cycle Normally Closed Master Valves
(NCMVs) open, so they are not included in the selection screen.
NCMVs will show as - and can not be changed.
b
e
Once you advance past the last MV, you will be returned to the
Special Features screen.
ESPLXD-ET user-manual (670504-01) artwork_120716.indb 143