27
ESPLXD-ET Controller
b
b
NOTE:
Station Priorities are only used when Station Sequencing
is set to Sequence by Station Priority. If you’re using the default
Sequence by Station Numbers, then skip the next step by pressing
Next.
E
Press the + and – buttons to set station priority. Each station can
be set to high, medium, low or Non-irrigation. Station priority is
especially important when multiple programs run simultaneously.
The controller will run all high priority stations first, then all
medium and finally all low priority, regardless of the station’s
program settings.
b
b
NOTE:
Non-irrigation stations such as fountains and landscape
lighting receive priority to always run, regardless of weather
conditions.
F
The FloZone Assignment screen lets you assign stations to
FloZones if you’re using either the FloWatch or FloManager
features. Press the + and – buttons to see available FloZones, or if
you’re not using FloZones, select zero; then press Next.
5
6
b
b
NOTE:
If you have already set up your MVs and FloZones, the MV
assignments for the currently selected FloZone will be shown in
the bottom portion of the screen.
G
The Weather Sensor Assignment screen lets you select which
weather sensors a particular station will obey. Press the + and –
buttons to set Y, for weather sensors which that station should
obey, or set N, for sensors which that station should ignore. Press
Next and Back to navigate between the WS fields.
7
b
b
NOTE:
All weather sensors, both decoder-based and local, can
be turned on (Active) or off (Bypassed) using the Weather Sensors
switch on the controller front panel. See Weather Sensors Setup
for more details.
b
e
Repeat this process to set up additional stations.