56
ESPLXD-ET Controller
Ping Decoders
The ESPLXD-ET controller can provide detailed information on a
specific decoder.
This can be helpful to narrow a repair trip into the field to one decoder
or a set of decoders on a particular branch of the two wire path. You can
ping a Station decoder, MV decoder or Sensor decoder. Interpretation
of the results is essentially the same for station and MV decoders.
Ping Station or MV Decoder
b
g
Turn the controller dial to Test All stations/Check System.
A
The System Diagnostics screen appears. Press the Down Arrow
button to select 2-Wire Diagnostics; then press Next.
B
The 2-Wire Diagnostics screen appears. Press the Down Arrow
button to select Ping Decoders; then press Next.
1
2
C
The Ping Decoder screen appears with Station Decoder selected.
Press Next to ping a Station decoder (or else press the Down
Arrow button to select MV Decoder); then press Next.
D
The Ping Station (or MV) Decoder screen appears. Press the + and
– buttons to select the desired Station (or MV); then press Ping.
3
4
E
The controller will ping the selected decoder and report;
amperage Prior to the ping, plus In-Rush and Holding current, all
in milliamps.
5
Interpreting Ping Results
b
l
The Prior amperage is based on line current for your system and
should be about the same as the previously Calculated System
Amperage.
b
l
The In-Rush current reading is typically less than 200 mA. A reading
of 100 mA or less typically indicates an open output, often caused
by a poor connection from the solenoid to the valve.