Appendix B: Tape Alert Flag Descriptions
276
Quantum Scalar i40 and Scalar i80 User’s Guide
Table 8 Tape Alert Flag
Descriptions
No. Flag
Severity
Recommended Application Client
Message
Probable Cause
1
Read warning
W
The tape drive is having problems
reading data. No data has been lost,
but there has been a reduction in the
performance of the tape.
The drive is having
severe trouble
reading.
2
Write warning
W
The tape drive is having problems
writing data. No data has been lost, but
there has been a reduction in the
capacity of the tape.
The drive is having
severe trouble
writing.
3
Hard error
W
The operation has stopped because an
error has occurred while reading or
writing data which the drive cannot
correct.
The drive had a hard
read or write error.
4
Media
C
Your data is at risk:
1
Copy any data you require from this
tape.
2
Do not use this tape again.
3
Restart the operation with a different
tape.
Media can no longer
be written/read, or
performance is
severely degraded.
5
Read failure
C
The tape is damaged or the drive is
faulty. Call the tape drive supplier help
line.
The drive can no
longer read data
from the tape.
6
Write failure
C
The tape is from a faulty batch or the
tape drive is faulty:
1
Use a good tape to test the drive.
2
If the problem persists, call the tape
drive supplier help line.
The drive can no
longer write data to
the tape.
Содержание Scalar i40
Страница 16: ...Figures xvi Quantum Scalar i40 and Scalar i80 User s Guide...
Страница 18: ...Tables xviii Quantum Scalar i40 and Scalar i80 User s Guide...
Страница 22: ...Preface xxii Quantum Scalar i40 and Scalar i80 User s Guide...
Страница 26: ...Preface xxvi Quantum Scalar i40 and Scalar i80 User s Guide...
Страница 312: ...Appendix C Disposal of Electrical and Electronic Equipment 286 Quantum Scalar i40 and Scalar i80 User s Guide...
Страница 327: ...Index Quantum Scalar i40 and Scalar i80 User s Guide 301 WORM 11 write protecting cartridges 265...
Страница 328: ...Index 302 Quantum Scalar i40 and Scalar i80 User s Guide...