Appendix A: Specifications
Environmental Specifications
Quantum Scalar i40 and Scalar i80 User’s Guide
271
Environmental Specifications
The environmental specifications of the library are listed below.
Note:
Temperature ranges apply to product inlet temperatures, not
necessarily to ambient room temperatures. Airflow restrictions
or other heat-generating equipment within the rack enclosure
may cause a rise over ambient room temperatures.
Air Clearance Requirements
There must be at least 4 in. (10 cm) of open space in front of and behind
the library for proper air flow
Operating
Non-Operating
Shipping and Storage
Altitude
–500 to 10,000 ft
(–152 to 3,048 m)
–500 to 10,000 ft
(–152 to 3,048 m)
–500 to 10,000 ft
(–152 to 3,048 m)
Temperature
50º to 95º F
(10º to 35º C)
50º to 113º F
(10º to 45º C)
–40º to 140º F
(–40º to 60º C)
Relative Humidity
20 to 80%,
non-condensing
10 to 90%,
non-condensing
0 to 95%,
non-condensing
Содержание Scalar i40
Страница 16: ...Figures xvi Quantum Scalar i40 and Scalar i80 User s Guide...
Страница 18: ...Tables xviii Quantum Scalar i40 and Scalar i80 User s Guide...
Страница 22: ...Preface xxii Quantum Scalar i40 and Scalar i80 User s Guide...
Страница 26: ...Preface xxvi Quantum Scalar i40 and Scalar i80 User s Guide...
Страница 312: ...Appendix C Disposal of Electrical and Electronic Equipment 286 Quantum Scalar i40 and Scalar i80 User s Guide...
Страница 327: ...Index Quantum Scalar i40 and Scalar i80 User s Guide 301 WORM 11 write protecting cartridges 265...
Страница 328: ...Index 302 Quantum Scalar i40 and Scalar i80 User s Guide...