Chapter 8: Installing, Removing, and Replacing Components
Removing and Installing a Power Supply
220
Quantum Scalar i40 and Scalar i80 User’s Guide
10
Run the magazine diagnostics test on the replaced magazine to be
sure it is functioning correctly.
a
Place a scratch tape in the top I/E station slot.
b
If manual cartridge assignment is enabled, assign the scratch
tape to the System partition.
c
From the operator panel, select
Tools > Diagnostics
.
d
Continue through the next few screens to run the magazine test
on the replaced magazine.
If a problem is found during testing, you receive a diagnostic ticket.
See
Running the IVT Diagnostic Subtests Individually – Robotics,
Tape Drive, and Magazine Tests
on page 257 more information.
Removing and Installing a Power Supply
The Scalar
®
i40 contains one power supply. The Scalar i80 can have up
to two power supplies for redundancy purposes.
An unused power supply slot must be covered by a filler plate.
This document covers:
•
Replacing a Power Supply in a Single-Power-Supply System (Scalar
i40 and Scalar i80)
•
Adding or Replacing a Redundant Power Supply on the Scalar i80
Содержание Scalar i40
Страница 16: ...Figures xvi Quantum Scalar i40 and Scalar i80 User s Guide...
Страница 18: ...Tables xviii Quantum Scalar i40 and Scalar i80 User s Guide...
Страница 22: ...Preface xxii Quantum Scalar i40 and Scalar i80 User s Guide...
Страница 26: ...Preface xxvi Quantum Scalar i40 and Scalar i80 User s Guide...
Страница 312: ...Appendix C Disposal of Electrical and Electronic Equipment 286 Quantum Scalar i40 and Scalar i80 User s Guide...
Страница 327: ...Index Quantum Scalar i40 and Scalar i80 User s Guide 301 WORM 11 write protecting cartridges 265...
Страница 328: ...Index 302 Quantum Scalar i40 and Scalar i80 User s Guide...