Chapter 9: Troubleshooting
About Diagnostic Tickets
244
Quantum Scalar i40 and Scalar i80 User’s Guide
About
Diagnostic Tickets
The library uses advanced problem detection, reporting, and
notification technology to alert you of problems as soon as they occur.
The library performs numerous self-tests to monitor the library’s
temperature, voltage and currents, and standard library operations. It
performs these self-tests each time the library is powered on and during
normal operation when the library is idle.
If the self-test detects a problem, the library generates a diagnostic
ticket that identifies the component that is likely causing the problem. If
the problem is not severe, the library continues to provide full
functionality to all unaffected partitions.
The tickets are assigned one of three priority levels:
• Low — The lowest level of priority. A ticket with low priority
indicates that an abnormal condition existed within the library that
warrants investigation and correction but the nature of the
condition may have little or no effect on operations.
• High — The middle level of priority. A ticket with high priority
indicates that a condition exists within the library that impacts
system performance or redundancy. Typical library operations can
continue without immediate corrective action, but a user should
investigate the condition and correct the problem soon.
• Urgent — The highest level of priority. A ticket with urgent priority
indicates that a failure has occurred or a serious condition exists
within the library that requires immediate corrective action. In most
cases, a hardware component is no longer functioning at an
acceptable level or has failed. Typical library operations required for
backup or restore are either not possible or highly unreliable.
The library has a number of visual cues to alert you that one or more
diagnostic tickets exist:
• The library’s ticket indicator LED turns on to indicate that at least
one ticket exists (see
Front Panel LEDs
on page 251).
• The operator panel displays a health status icon (see
Health status
on page 29 for description).
• The Web client displays a subsystem status icon (see
Subsystem
Status
on page 35).
Содержание Scalar i40
Страница 16: ...Figures xvi Quantum Scalar i40 and Scalar i80 User s Guide...
Страница 18: ...Tables xviii Quantum Scalar i40 and Scalar i80 User s Guide...
Страница 22: ...Preface xxii Quantum Scalar i40 and Scalar i80 User s Guide...
Страница 26: ...Preface xxvi Quantum Scalar i40 and Scalar i80 User s Guide...
Страница 312: ...Appendix C Disposal of Electrical and Electronic Equipment 286 Quantum Scalar i40 and Scalar i80 User s Guide...
Страница 327: ...Index Quantum Scalar i40 and Scalar i80 User s Guide 301 WORM 11 write protecting cartridges 265...
Страница 328: ...Index 302 Quantum Scalar i40 and Scalar i80 User s Guide...