PT113
Instruction Manual
54
PLC Output to PT113EI Input
Bitwise order of a Dword:
Dword
(R/W)
D31 D30 D29 D28 D27 D26 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16
D15 D14 D13 D12 D11 D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
1
st
Dword
Not
Used
2
nd
Dword
Next Dword defines the usage of this Dword.
3
rd
Dword
Not in use
Command List
Read Data Selection
New
CMD
PLC Output to PT113EI Input 3
rd
Dword
Bit Number
3
rd
Dword descriptions
D31 ... D11
Not in use
D10 … D6
Command
List
Bin
Dec
Commands
00000
0
No command is activated
00001
1
Zero
00010
2
Tare
00011
3
Clear
00100
4
Not in use
00101
5
Adjust zero calibration
Calibration
00110
6
Adjust span calibration
(1)
00111
7
Not in use
01000
8
Operating mode
selection
(1)
0: Count mode unipolar
1: Count mode bipolar
2: Force mode unipolar
3: Force mode bipolar
4: Weight mode unipolar
01001
9
Input range (mV) for
Count Mode
(1)
0: 5 mV (1mV/V)
1: 10 mV (2mV/V)
2: 15 mV (3mV/V)
3: 18 mV (3.6mV/V)
01010
10
Digital Filter
(1)
0: Fast
…
5: Medium
…
7: Default
…
9: Slow
D5... D1
Read Data
Selection
00000
0
Indicated weight (Gross or Net) as 32 bit integer
00001
1
Gross weight as 32 bit integer
00010
2
Tare weight as 32 bit integer
00011
3
Indicated weight (Gross or Net) as Floating point
00100
4
Gross weight as Floating point
00101
5
Tare weight as Floating point
00110 -
01111
6 -15
Not used
10000
16
Calibration status (refer to table above)
D0
New CMD
Toggle
Apply commands which are listed in this table
(1) Write this command after writing values to 2
nd
Dword , then apply this command with New CMD