When changing a hot end always remove the filament before starting and always remove when
the hot end is at full temperature (230
°C
. (Refer to 11.7)
We recommend allowing your hotend to cool before changing.
Loosen the hotend clamp and grip the hotend with large pliers around the aluminium heater
block.
Take care not to crush the thermistor and resistor cables. Slide the hotend down and out of the
extruder and through the hotend clamp. Then disconnect the cables.
When changing a hot end always check that the PTFE disc stays in place in the extruder recess.
Always check for debris in the extruder and hotend. If your hotend will remain out of your printer
for some time place a strip of kapton tape over the hole and ensure the brass nib does not get
damaged.
Refit or install your replacement by sliding through the hotend clamp and in to the extruder
recess. Ensure it is all the way in and tighten the hot end clamp. Always check the Z endstop
home position after changing hotends.
11.0 Commissioning & Calibration - Reprap Prusa Mendel Build Manual
©2012 NextDayReprap
Prusa Mendel Kit Build Manual V1.01 - 07/2012
11.9 Changing Hotends